BLOWER MOTOR RESISTOR REPLACEMENT - CONTINUED
BLOWER MOTOR RESISTOR REPLACEMENT - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1296    1297    1298    1299    1300  1301  1302    1303    1304    1305    1306  
img
TM 5-3805-291-23-1
BLOWER MOTOR RESISTOR REPLACEMENT - CONTINUED
0049 00
REMOVAL - CONTINUED
3.
Remove bolt (5), washer (6), two washers (7), washers
(8) and resistor (10) from bracket (11).
N OT E
Note location of wires prior to discon-
necting from resistor.
4.
Disconnect three wires (9) from resistor (10) and
remove resistor from machine.
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user
must wear protective goggles or face shield. Failure to follow this warning may result in injury to per-
sonnel.
1.
Clean all parts and mating surfaces with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
0049 00-3