• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
HVAC BLEND DOOR ACTUATOR REPLACEMENT - CONTINUED
HVAC BLEND DOOR ACTUATOR REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
TM 5-3805-291-23-2
HVAC BLEND DOOR ACTUATOR REPLACEMENT - CONTINUED
0052 00
REMOVAL - CONTINUED
7.
Remove screw (11) from cover assembly (5).
8.
Remove cover assembly (5) from machine.
9.
Disconnect harness (13) from actuator (15).
10.
Remove three bolts (14) and actuator (15) from housing (12).