STARTER REPLACEMENT - CONTINUED
HVAC BLEND DOOR ACTUATOR REPLACEMENT

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
img
TM 5-3805-291-23-2
STARTER REPLACEMENT - CONTINUED
0051 00
PINION CLEARANCE ADJUSTMENT - CONTINUED
7.
If clearance is not correct, remove plug on pinion drive housing. Turn adjustment nut until clearance is correct. Turning
nut clockwise will decrease clearance (X).
N OT E
The plunger may turn when the adjustment nut is being turned. If the plunger turns, disconnect the battery
from the solenoid. Remove the solenoid from the starting motor. Hold the plunger from the turning and
adjust the nut. This procedure may need to be performed several times until the correct clearance is
obtained.
8.
Disconnect the batteries from solenoid and install plug in shift lever housing.
END OF WORK PACKAGE
0051 00-9/(0051 00-10 Blank)