STARTER REPLACEMENT - CONTINUED
HVAC BLEND DOOR ACTUATOR REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  20    21    22    23    24  25  26    27    28    29    30  
img
. . . . . . .
10
TM 5-3805-291-23-2
HVAC BLEND DOOR ACTUATOR REPLACEMENT
0052 00
THIS WORK PACKAGE COVERS
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Maintenance Level
References
TM 5-3805-291-10
Unit
Equipment Conditions
Tools and Special Tools
Machine parked on level ground (TM 5-3805-291-
Tool kit, general mechanic's, automotive (Item 90,
10)
WP 0232 00)
Work tool lowered to ground (TM 5-3805-291-10)
Shop equipment, automotive maintenance and
repair: organizational maintenance, common no.
Parking brake engaged (TM 5-3805-291-10)
1 (Item 70, WP 0232 00)
Wheels chocked
Battery disconnect switch in OFF position (TM 5-
Materials/Parts
3805-291-10)
Cleaning compound, solvent, type III (Item 7, WP
0233 00)
Drawings Required
Primer coating (Item 34, WP 0233 00)
TM 5-3805-291-23P, Figure 172
Personnel Required
Estimated Time to Complete Task
1.5 hr
MOS 62B, Construction Equipment Repairer
0052 00-1