HVAC BLEND DOOR ACTUATOR REPLACEMENT - CONTINUED
FUSE, RELAY, CIRCUIT BREAKER, AND ARC SUPPRESSOR REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  30    31    32    33    34  35  36    37    38    39    40  
img
. . . . . .
10
TM 5-3805-291-23-2
FUSE, RELAY, CIRCUIT BREAKER, AND ARC SUPPRESSOR REPLACEMENT
0053 00
THIS WORK PACKAGE COVERS
Fuse: Removal, Installation
Hood Tilt Relay: Removal, Installation
Cab Circuit Breaker: Removal, Installation
Panel Box Circuit Breaker: Removal, Installation
Arc Suppressor: Removal, Installation
INITIAL SETUP
References
Maintenance Level
Unit
TM 5-3805-291-10
Tools and Special Tools
Equipment Conditions
Tool kit, general mechanic's, automotive (Item 90,
WP 0232 00)
Right rear interior cover removed (interior wiring)
(WP 0138 00)
Materials/Parts
Rag, wiping (Item 35, WP 0233 00)
Drawings Required
Tag, marker (Item 43, WP 0233 00)
TM 5-3805-291-23P, Figures 51 and 56
Tiestraps
Estimated Time to Complete Task
Personnel Required
0.3 hr
MOS 62B, Construction Equipment Repairer
FUSE REMOVAL
0053 00
WARN I N G
Ensure battery disconnect switch is in OFF position before performing this task. Failure to follow this
warning may result in injury to personnel or damage to equipment.
C AU T I O N
Replace fuses with same type and size only. Otherwise, electrical damage can result.
N OT E
These procedures show one fuse, relay, or circuit replacement. Replacement is the same for each fuse,
relay, or circuit.
Refer to inside cover of fuse box for fuse locations.
Tag wiring harnesses prior to disconnection to ensure correct installation.