Table 2. Powertrain ECM Replacement.
STOPLIGHT LIMIT SWITCH MAINTENANCE - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  100    101    102    103    104  105  106    107    108    109    110  
img
. . . . .
4
TM 5-3805-291-23-2
STOPLIGHT LIMIT SWITCH MAINTENANCE
0064 00
THIS WORK PACKAGE COVERS
Removal, Installation, Adjustment
INITIAL SETUP
Equipment Conditions
Maintenance Level
Machine parked on level ground (TM 5-3805-291-
Unit
10)
Tools and Special Tools
Work tool lowered to ground (TM 5-3805-291-10)
Tool kit, general mechanic's, automotive (Item 90,
Parking brake engaged (TM 5-3805-291-10)
WP 0232 00)
Wheels chocked
Shop equipment, automotive maintenance and
Battery disconnect switch in OFF position (TM 5-
repair: organizational maintenance, common no.
3805-291-10)
1 (Item 70, WP 0232 00)
Drawings Required
Materials/Parts
TM 5-3805-291-23P, Figure 56
Rag, wiping (Item 35, WP 0233 00)
Estimated Time to Complete Task
Personnel Required
0.5 hr
MOS 62B, Construction Equipment Repairer
WARN I N G
Ensure battery disconnect switch is in OFF position before performing this task. Failure to follow this
warning may result in injury to personnel or damage to equipment.