TURNLAMP SWITCH REPLACEMENT - CONTINUED
WINDSHIELD WIPER SWITCHES REPLACEMENT

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  107    108    109    110    111  112  113    114    115    116    117  
img
TM 5-3805-291-23-2
TURNLAMP SWITCH REPLACEMENT - CONTINUED
0066 00
REMOVAL - CONTINUED
5.
Remove three screws (9) from turnlamp switch (5).
427-C1315
N OT E
Tag wires prior to removal to ensure correct installation.
6.
Disconnect six wires (10) from turnlamp switch (5).
7.
Remove turnlamp switch (5) from bracket (11).
INSTALLATION
1.
Position turnlamp switch (5) on bracket (11).
2.
Connect six wires (10) to turnlamp switch (5).
3.
Install three screws (9) on turnlamp switch (5).
4.
Install cover (8), four screws (6), and washers (7) on
turnlamp switch (5).
427-C1316
5.
Install lever (2) on turnlamp switch (5).
6.
Install washer (4) and screw (3) on lever (2).
7.
Install plate (1) on lever (2).
8.
Verify correct turnlamp operation (TM 5-3805-291-10).
END OF WORK PACKAGE
0066 00-3/(0066 00-4 Blank)