TM 5-3805-291-23-2
TRANSMISSION SERVICE - CONTINUED
0100 00
N OT E
Magnetic strainer is located on right side of transfer case.
8.
Remove four bolts (3) and washers (4) from magnetic strainer cover (5).
9.
Remove magnetic strainer cover (5) and O-ring (6) from transfer case housing (7). Discard O-ring.
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition. Failure to do so may result in injury
or death to personnel.
N OT E
Check bottom of strainer to ensure cor-
rect orientation during installation.
10.
Remove and clean screen (8) and magnet assembly (9)
with solvent.
427-C0130
0100 00-3