TRANSMISSION SERVICE - CONTINUED
TRANSMISSION SERVICE - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  226    227    228    229    230  231  232    233    234    235    236  
img
TM 5-3805-291-23-2
TRANSMISSION SERVICE - CONTINUED
0100 00
FILLING
1.
Install magnet assembly (9) and screen (8) in transfer case housing (7).
2.
Apply a thin coat of clean lubricating oil to new O-ring (6) and install O-ring and strainer cover (5) on transfer case
housing (7).
3.
Install four washers (4) and bolts (3) in strainer cover
(5).
4.
Install new O-ring on drain plug (1).
5.
Install transmission oil drain plug (1) in bottom of
transfer case (2).
N OT E
Transmission oil filler cap and tube
are located on left-side of machine.
Transmission capacity is 13.2 gal.
(50 L).
6.
Remove transmission oil filler cap (10) from fill
tube (11).
7.
Fill transmission with oil.
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition. Failure to do so may result in injury
or death to personnel.
8.
Use solvent cleaning compound to clean and inspect
transfer case breather (12) located on top of transfer
case (2).
427-C0132
0100 00-4


Privacy Statement