TM 5-3805-291-23-2
PILOT OIL ACCUMULATOR MAINTENANCE - CONTINUED
0150 00
TEST AND CHARGE - CONTINUED
WAR N I N G
Before operating the machine, secure the steering frame lock in the stowed position. DO NOT operate
machine with steering frame lock connected. Failure to lock steering frame lock into the stowed position
before operating can result in loss of steering and injury or death to personnel.
11.
Secure steering frame lock in stowed position (TM 5-3805-291-10).
12.
Pressurize hydraulic system (TM 5-3805-291-10).
13.
Check hydraulic fluid level (TM 5-3805-291-10).
14.
Run engine until normal operating temperature is reached (TM 5-3805-291-10).
15.
Shut down engine (TM 5-3805-291-10).
16.
Check for leaks.
END OF WORK PACKAGE
0150 00-8