RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED
RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  557    558    559    560    561  562  563    564    565    566    567  
img
TM 5-3805-291-23-2
RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED
0151 00
REMOVAL - CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting equipment used is in good condition and of suitable load capacity. Keep
clear of heavy parts supported only by lifting equipment. Failure to follow this warning may result in injury
or death to personnel.
N OT E
Ride control accumulator weighs 97 lb (44 kg).
4.
Attach lifting equipment to ride control accumulator (1).
5.
With assistance, remove four bolts (5) and washers (6) from ride control accumulator (1) and remove ride control accu-
mulator from machine.
6.
Remove elbow (3) from ride control accumulator (1).
7.
Remove O-ring (7) from elbow (3). Discard O-ring.
427-C1119