TM 5-3805-291-23-2
RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED
0151 00
DISCHARGING/CHARGING - CONTINUED
1.
Remove protective cap from nitrogen charging valve (8).
N OT E
DO NOT attach hose assembly to T (10) when discharging accumulator.
2.
Attach hose assembly (9) to nitrogen charging chuck (11).
3.
Turn valve handle (12) on nitrogen charging chuck (11) counterclockwise to ensure nitrogen charging valve (8) will not
open when nitrogen charging chuck is attached to nitrogen charging valve.
4.
Attach nitrogen charging chuck (11) and hose assembly (9) to nitrogen charging valve (8).
WAR N I N G
Point open end of hose assembly away from work area and personnel. Failure to follow this warning may
result in injury to personnel.
5.
Place open end of hose assembly (9) away from work area and other personnel.
6.
Turn valve handle (12) on nitrogen charging chuck (11) fully clockwise to open nitrogen charging valve (8). Release all
compressed gas from ride control accumulator through hose assembly (9). Remove ride control accumulator from
machine.
427-C1121
427-C1122
0151 00-7