RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED
Nitrogen Charging Procedure

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  561    562    563    564    565  566  567    568    569    570    571  
img
TM 5-3805-291-23-2
RIDE CONTROL ACCUMULATOR MAINTENANCE - CONTINUED
0151 00
DISCHARGING/CHARGING - CONTINUED
Discharging Ride Control Accumulator
1.
Remove protective cap from nitrogen charging valve (8).
N OT E
DO NOT attach hose assembly to T (10) when discharging accumulator.
2.
Attach hose assembly (9) to nitrogen charging chuck (11).
3.
Turn valve handle (12) on nitrogen charging chuck (11) counterclockwise to ensure nitrogen charging valve (8) will not
open when nitrogen charging chuck is attached to nitrogen charging valve.
4.
Attach nitrogen charging chuck (11) and hose assembly (9) to nitrogen charging valve (8).
WAR N I N G
Point open end of hose assembly away from work area and personnel. Failure to follow this warning may
result in injury to personnel.
5.
Place open end of hose assembly (9) away from work area and other personnel.
6.
Turn valve handle (12) on nitrogen charging chuck (11) fully clockwise to open nitrogen charging valve (8). Release all
compressed gas from ride control accumulator through hose assembly (9). Remove ride control accumulator from
machine.
427-C1121
427-C1122
0151 00-7