BUCKET LIFT ARMS REPLACEMENT - CONTINUED
BUCKET LIFT ARMS REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1223    1224    1225    1226    1227  1228  1229    1230    1231    1232    1233  
img
TM 5-3805-291-23-2
BUCKET LIFT ARMS REPLACEMENT - CONTINUED
0229 00
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user
must wear protective goggles or face shield. Failure to follow this warning may result in injury to per-
sonnel.
1.
Clean all parts and mating surfaces with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
4.
Inspect oil passages to ensure they are clean and unobstructed.
0229 00-9


Privacy Statement