Figure 2. Front of SSL.
Figure 5. Axle Mounting Bolts and Chain Tank (M400W).

Operators Manual For M400T And M400W
Page Navigation
  140    141    142    143    144  145  146    147    148    149    150  
img
.
TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
SERVICE
Before
Attachment
3
(Cont)
Coupler and
Work Tool
Attachment
LOCKING LEVERS IN
458-0011
HORIZONTAL LOCKED POSITION
Figure 3. Work Tool Attachment Locked to Attachment Coupler.
0020
c. If work tool attachment is not
Locking levers do not lock.
installed, ensure two locking
levers can be turned to
horizontal locked position and
latch pins fully extend.
4
Inspect two quick disconnect hose
Before
Auxiliary
Class III leaks are evident.
Hydraulic Hose couplers for looseness, damage,
Damage that would impair
and leaks.
operation is evident.
Couplers
AUXILIARY HYDRAULIC
HOSE COUPLERS
458-0012
Figure 4. Quick Disconnect Hose Couplers.
0020
0020-5