ELECTRICAL TROUBLESHOOTING - WINDSHIELD WIPER AND BLOWER MOTOR INOPERABLE/EC012 GRID HEATER CIRCUIT TO ENGINE PREHEAT RELAY IS OPEN
ELECTRICAL TROUBLESHOOTING - INSTRUMENT PANEL (IP) DOES NOT POWER UP WHEN SEAT IS OCCUPIED

Field Maintenance Manual For M400T And M400W
Page Navigation
  66    67    68    69    70  71  72    73    74    75    76  
img
. . . . . . . . . . . . . . .
TM 5-3805-292-23
0006
ELECTRICAL TROUBLESHOOTING - MACHINE AND LOADER ARMS WILL NOT MOVE/
EC013 PARKING BRAKE CIRCUIT TO BRAKE VALVE IS OPEN
0006
Refer to Malfunction One Drive
Motor (Right or Left) Works
Problem still
Stop.
NO
Correctly and the Other Does Not
exists?
in this WP.
YES
Disconnect instrument panel (IP)
(WP 0155).
Disconnect brake release solenoid
(WP 0070).
Check for continuity between IP
Perform Open Harness Test for circuit
Continuity
connector C23-8, circuit 258A (T),
NO
present?
258 (WP 0173).
harness side and solenoid
connector 80-A, circuit 258B (T),
harness side (WP 0175, Frame 12.
RH Console and Frame 19.
Miscellaneous Circuits).
YES
Check for continuity between
Repair circuit 178AL (B) or replace
solenoid connector 80-B, circuit
chassis wiring (WP 0146). Reconnect
Continuity
178AL (B), harness side and
NO
instrument panel (IP) (WP 0155) and
present?
ground (WP 0175, Frame 19.
brake release solenoid (WP 0070).
Miscellaneous Circuits).
YES
Reconnect instrument panel (IP) (WP
0155). Replace brake release solenoid
(WP 0070).
0006-43