ELECTRICAL TROUBLESHOOTING - INSTRUMENT PANEL (IP) DOES NOT POWER UP WHEN SEAT IS OCCUPIED
ELECTRICAL TROUBLESHOOTING - HORN INOPERATIVE

Field Maintenance Manual For M400T And M400W
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
. . . . . . . . . . . . . . . . . .
TM 5-3805-292-23
0006
ELECTRICAL TROUBLESHOOTING - JOYSTICK PARKING BRAKE BUTTON INOPERATIVE
0006
Disconnect RH control handle
from chassis harness (WP 0084).
While pressing and releasing park
button, check for continuity
Continuity present
between RH control handle
w/ button pressed?
Replace RH control handle
connector 49B-2 circuit 319AB
Continuity NOT
NO
(WP 0084).
(R), handle side and RH control
present w/button
handle connector circuit 754AB
released?
(P), handle side
(WP 0175, Frame 6. Handle
Connections) .
YES
Disconnect instrument panel (IP) (WP
0155).
Check for continuity between IP
connector C23-26, circuit 319C (T),
Perform Open Harness Test for circuit
Continuity
harness side and RH control handle
NO
present?
319 (WP 0173).
connector, 49-1 circuit 319G (T), harness
side (WP 0175, Frame 6. Handle
Connections and Frame 12. RH
Console).
YES
Check for continuity between IP
connector C23-10, circuit 754B (P),
Reconnect instrument panel (IP) (WP
harness side and RH control handle
Continuity
0155). Perform Open Harness Test for
NO
connector 49-2 circuit 754A (P),
present?
circuit 754 (WP 0173).
harness side (WP 0175, Frame 12.
RH Console).
YES
Reconnect RH control handle to chassis
harness (WP 0084). Replace instrument
panel (WP 0155).