ELECTRICAL TROUBLESHOOTING - ONE OR MORE EXTERIOR LIGHT(S) INOPERATIVE CONTINUED
CHASSIS TROUBLESHOOTING - BLOWER MOTOR INOPERATIVE/DOES NOT OPERATE CORRECTLY

Field Maintenance Manual For M400T And M400W
Page Navigation
  80    81    82    83    84  85  86    87    88    89    90  
img
. . . . . . . . . . . . . . . . . . . . . .
TM 5-3805-292-23
0006
ELECTRICAL TROUBLESHOOTING - ONE OR MORE EXTERIOR LIGHT(S) INOPERATIVE CONTINUED
AA
Disconnect rear position light
(WP 0163).
12V
Perform Open Harness Test for
Measure voltage between work light
NO
connector 35 or 37, circuit 790U or
present?
circuit 790 (WP 0173).
790V (P), harness side, and ground
(WP 0175, Frame 25. Lights).
YES
Check continuity between work light
connector 35 or 37, circuit 178AJ or
Continuity
Repair circuit 178 or replace wiring
178AK (B), harness side, and
NO
present?
chassis harness (WP 0146).
ground (WP 0175, Frame 25.
Lights).
YES
Reconnect rear position light (WP 0163).
AM
Check for continuity between light
Continuity
Repair circuit 178 or replace chassis
relay # 2 connector pin 85 and
NO
ground (WP 0175, Frame 10.
present?
wiring harness (WP 0146).
Power Center).
YES
Measure voltage between light
relay #2 connector pin 86, circuit
12V
Replace light relay #2
790K (P), fuse box side, and
YES
present?
(TM 5-3805-292-10).
ground (WP 0175, Frame 10.
Power Center).
NO
Disconnect work light switch
(WP 0166).
Check for continuity between work light
Reinstall work light switch (WP
Continuity
switch connector 311-3, circuit 790E (R),
0166). Perform Open Harness Test
NO
harness side and light relay #2
present?
for circuit 790 (WP 0173).
connector pin 86, circuit 790K (P), and
fuse box (WP 0175, Frame 10. Power
Center and Frame 12. RH Console).
YES
Replace work light switch (WP 0166).
END OF TASK