• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CHASSIS TROUBLESHOOTING - BLOWER MOTOR INOPERATIVE/DOES NOT OPERATE CORRECTLY - CONTINUED
CHASSIS TROUBLESHOOTING - WINDSHIELD WASHER/WIPER INOPERATIVE/DOES NOT OPERATE CORRECTLY CONTINUED

Field Maintenance Manual For M400T And M400W
Page Navigation
  85    86    87    88    89  90  91    92    93    94    95  
img
. . . . . . . . . . . . . . . . .
TM 5-3805-292-23
0006
CHASSIS TROUBLESHOOTING - WINDSHIELD WASHER/WIPER
INOPERATIVE/DOES NOT OPERATE CORRECTLY
0006
Check 10A wiper/washer fuse
Fuse
Replace fuse (TM 5-3805-292-10).
NO
okay?
(TM 5-3805-292-10).
YES
Test opt power relay #1
Replace opt power relay #1
Relay
NO
okay?
(WP 0173).
(TM 5-380-292-10).
YES
Remove opt power relay #1 (TM
5-3805-292-10).
Measure voltage between opt
12V
Perform Open Harness Test for
power relay #1 pin 30, circuit
NO
present?
circuit 120 (WP 0173).
120H (R), fuse box side, and
ground (WP 0175, Frame 9.
Power Center).
YES
Measure voltage between opt
power relay #1 pin 86, circuit
12V
Perform Open Harness Test for
137F (R), fuse box side, and
NO
present?
circuit 137 (WP 0173).
ground (WP 0175, Frame 9.
Power Center).
YES
Remove 10A wiper/washer fuse
(TM 5-3805-292-10).
Check for continuity between
Continuity
wiper/washer fuse, circuit 138C
Perform Open Harness Test for
NO
(R), fuse box side, and opt power
present?
circuit 138 (WP 0173).
relay #1 pin 87, circuit 138A (R),
fuse box side (WP 0175, Frame
9. Power Center).
YES
Check for continuity between
opt power relay #1 pin 85 fuse
Continuity
Repair ground to relay (WP 0173).
NO
box side, and ground (WP
present?
0175, Frame 9. Power Center).
YES
Install fuse and relay.
AE
CONTINUED
(page 0006-63)
0006-62