TM 5-3805-292-23
0029
CLEANING AND INSPECTION
00029
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00029
N OT E
Position components as noted during removal.
1. Loosely install gasket (Figure 1, Item 11), engine air duct heater (Figure 1, Item 12), gasket (Figure 1, Item 13),
duct (Figure 1, Item 4), cable (Figure 1, Item 8), and four bolts (Figure 1, Item 5) on intake manifold (Figure 1,
Item 7) and hose (Figure 1, Item 3).
N OT E
Install cables as tagged during removal.
2. Install cable (Figure 1, Item 8) and nut (Figure 1, Item 9) on heater (Figure 1, Item 12).
3. Install cable (Figure 1, Item 6) and nut (Figure 1, Item 10) on heater (Figure 1, Item 12).
4. Torque four bolts (Figure 1, Item 5) to 18.5 lb-ft (25 Nm).
5. Install clamp (Figure 1, Item 2) and hose (Figure 1, Item 3) on turbocharger (Figure 1, Item 1) and tighten
clamp on hose.
END OF TASK
0029-3