TM 5-3805-292-23
0047
CLEANING AND INSPECTION CONTINUED
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
4. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00047
N OT E
Install all wires and wiring harnesses as noted during removal.
1. Install new gasket (Figure 1, Item 8), thermostat and housing (Figure 1, Item 9), and four bolts (Figure 1, Item
10) on machine.
2. Install plug (Figure 1, Item 2) on thermostat and housing (Figure 1, Item 9).
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy
and ordinances. Failure to follow this warning may result in injury to personnel.
3. Apply sealing compound to threads of coolant temperature sender (Figure 1, Item 6).
4. Install coolant temperature sender (Figure 1, Item 6) on thermostat and housing (Figure 1, Item 9).
5. Install hose (Figure 1, Item 1) and clamp (Figure 1, Item 11) on thermostat and housing (Figure 1, Item 9).
6. Install wire (Figure 1, Item 7), washer (Figure 1, Item 5), new lockwasher (Figure 1, Item 4), and nut (Figure 1,
Item 3) on coolant temperature sender (Figure 1, Item 6).
END OF TASK
0047-3