TM 5-3805-292-23
0047
REMOVAL
00047
N OT E
Tag all wires and wiring harnesses to aid in installation.
1. Remove nut (Figure 1, Item 3), lockwasher (Figure 1, Item 4), washer (Figure 1, Item 5), and wire (Figure 1,
Item 7) from coolant temperature sender (Figure 1, Item 6). Discard lockwasher.
2. Remove coolant temperature sender (Figure 1, Item 6) from thermostat and housing (Figure 1, Item 9).
3. Remove plug (Figure 1, Item 2) from thermostat and housing (Figure 1, Item 9).
4. Loosen clamp (Figure 1, Item 11) and disconnect hose (Figure 1, Item 1) from thermostat and housing (Figure
1, Item 9).
5. Remove four bolts (Figure 1, Item 10), thermostat and housing (Figure 1, Item 9), and gasket (Figure 1, Item 8)
from machine. Discard gasket.
Figure 1. Thermostat and Housing.
0047
END OF TASK
CLEANING AND INSPECTION
00047
1. Remove all gasket material from mating surfaces.
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
2. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.