FIELD MAINTENANCE
-
TOP WINDOW REPLACEMENT
0122
REMOVAL, CLEANING AND INSPECTION, INSTALLATION
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's (WP 0178, Item
WP 0172
0
33)
TM 5-3805-292-23P, Figure 59
0
0
Materials/Parts
Equipment Conditions
0
0
Rag, Wiping (WP 0179, Item 19)
Machine parked on level ground (TM 5-3805-
0
Sealing Compound (Sika Flex) (WP 0179,
292-10)
0
Item 27)
0
Estimated Time to Complete
0
1.0 Hr
0
REMOVAL
000122
1. Scrape sealing compound (Figure 1, Item 1) from top window (Figure 1, Item 3).
2. Remove four interior bolts (Figure 1, Item 2) and two exterior bolts (Figure 1, Item 4) from top window (Figure
1, Item 3) and remove top window from machine.
Figure 1. Top Window.
0122
END OF TASK
CLEANING AND INSPECTION
000122
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK