TOP WINDOW REPLACEMENT
WEAPON RACK REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  817    818    819    820    821  822  823    824    825    826    827  
img
.
TM 5-3805-292-23
0122
INSTALLATION
000122
1. Position top window (Figure 2, Item 3) on ROPS assembly and install two exterior bolts (Figure 2, Item 4) and
four interior bolts (Figure 2, Item 2).
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of clean up rags IAW local policy
and ordinances. Failure to follow this warning may result in injury to personnel.
2. Apply sealing compound (Figure 2, Item 1) inside and outside top window (Figure 2, Item 3) at seam.
Figure 2. Top Window.
0122
END OF TASK
FOLLOW-ON TASKS
000122
Verify correct operation of window (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE