DELUXE HEATER A/C MAINTENANCE
Figure 2. A/C Hose Connections on Evaporator.

Field Maintenance Manual For M400T And M400W
Page Navigation
  878    879    880    881    882  883  884    885    886    887    888  
img
.
TM 5-3805-292-23
0130
REMOVAL
000130
1. Remove eight screws (Figure 1, Item 1) and two end cap covers (Figure 1, Item 3) from case (Figure 1, Item 2).
Figure 1. End Cap Covers and Retaining Hardware.
0130
WARN I N G
Make sure A/C system is evacuated completely before loosening A/C hose connectors.
Failure to follow this warning may result in injury to personnel.
N OT E
Tag and mark all hoses and lines to aid installation.
Cap all ports and open hoses immediately upon disconnection to prevent dirt from
entering system.
2. Disconnect two A/C hoses (Figure 2, Item 1) from case (Figure 2, Item 2).
0130-2