Table 1. E0539 High Intake Manifold Temperature Event Code - Continued.
Table 1. E0539 High Intake Manifold Temperature Event Code - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  370    371    372    373    374  375  376    377    378    379    380  
img
.
TM 5-3805-298-23-1
0026
Table 1. E0539 High Intake Manifold Temperature Event Code - Continued.
026
EID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
E0539 High Intake Manifold
Temperature Event Code -
Continued
If CBRN exposure is suspected, personnel wearing protective equipment
should handle all air cleaner media. Consult your CBRN Officer NCO for
appropriate handling or disposal procedures.
Refer to FM 3-11.3, Multiservice Tactics, Techniques, and Procedures for
Chemical, Biological, Radiological, and Nuclear Contamination
Avoidance and FM 3-11.5, Multiservice Tactics, Techniques, and
Procedures for Chemical, Biological, Radiological, and Nuclear
Decontamination.
Allow engine to cool off before performing maintenance on air cleaner.
Hot metal parts can cause severe burns. Wear eye, hand, and skin
protection when working with heated parts.
Failure to follow these warnings may result in injury or death to
personnel.
8. Release three clamps (Figure 8,
Item 2); remove air cleaner cover
(Figure 8, Item 1) and primary air
filter (Figure 8, Item 3) from
machine (WP 0204).