TM 5-3805-298-23-1
0029
Table 1. E0861 Clock Manual Alignment Required Event Code - Continued.
029
EID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2. Select Synchronize button
E0861 Clock Manual
(Figure 4, Item 5) at bottom of ET
Alignment Required Event
screen.
Code - Continued
3. Select Yes button (Figure 4,
Item 2) on the synchronize request
pop-up window (Figure 4, Item 1)
to synchronize service hours the
ECM.
4. Select the OK button (Figure 4,
Item 4) on the synchronize
success pop-up window (Figure 4,
Item 4).
5. Proceed to Test Step 3.
Figure 4. Service Menu.
0029
Test Step 3. Verify Symptom Is
Resolved.
Using MSD, check for active event code Event Code E0861 Is Active - Repeat
troubleshooting from the beginning.
Event Code E0861 Not Active -
Troubleshooting complete.
END OF WORK PACKAGE