Table 1. E0861 Clock Manual Alignment Required Event Code.
0029
EID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
Conditions Which Generate This
E0861 Clock Manual
Code:
Alignment Required Event
Code
The engine electronic control module
(ECM) detects the internal clock of the
ECM is too far out of alignment with the
other control module clocks that are on
the machine.
System Response:
Warning lamp on instrument panel will
be illuminated and event code will be
logged.
Possible Performance Effect:
None.
When an ECM is flashed, all configured
parameters are loaded with the new
software except for the system clocks.
If the system clocks for each ECM are
not synchronized correctly, the
transmission ECM will activate an
E0861.
Test Step 1. Check Total Operating
Hours.
Diagnostic Codes Not Active -
Transmission 924H, and check for
Proceed to step 2.
active diagnostic codes.
Diagnostic Codes Active - Refer to
codes first.
2. Confirm that the transmission ECM
Transmission ECM Replaced -
has been replaced.
Proceed to step 3.
Transmission ECM Not Replaced -
Proceed to Test Step 2.