Table 1. 2417 Start Aid Diagnostic Codes - Continued.
Table 1. 2417 Start Aid Diagnostic Codes - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  804    805    806    807    808  809  810    811    812    813    814  
img
.
TM 5-3805-298-23-1
0068
Table 1. 2417 Start Aid Diagnostic Codes - Continued.
068
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
6. Select Ether Injection (Figure 12,
2417-6 Ether Control
Item 1).
Solenoid Current Above
7. From the pop-up window
Normal - Continued
(Figure 12, Item 3), select the
down arrow (Figure 12, Item 4).
8. Select ON (Figure 12, Item 5) from
the drop down menu and select
OK (Figure 12, Item 6).
9. Select YES from pop-up window to
activate ether valve.
10. Using the MSD (WP 0008), check
Diagnostic Code 2417-6 Ether
for active diagnostic codes
Control Solenoid Current Above
Normal Becomes Inactive - Select the
(Figure 12, Item 8).
Disable Override button (Figure 12,
Item 7) to de-activate ether valve.
Select the Disconnect icon (Figure 12,
Item 2).
Turn ignition switch and battery
disconnect switch to the OFF position
(TM 5-3805-298-10).
Install ether bottle, if removed
(TM 5-3805-298-10).
Troubleshooting complete.
Diagnostic Code 2417-6 Ether
Control Solenoid Current Above
Normal Remains Active - Select the
Disable Override button (Figure 12,
Item 7) to de-activate ether valve.
Select the Disconnect icon (Figure 12,
Item 2).
Turn ignition switch and battery
disconnect switch to the OFF position
(TM 5-3805-298-10).
Repeat troubleshooting from the
beginning.
0068-24