TM 5-3805-298-23-1
0116
Table 1. 1834 Ignition Key Switch (Transmission) Diagnostic Codes - Continued.
0116
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1834-2 Ignition Key Switch
(WP 0174), measure resistance
Replace ignition switch (WP 0254).
Circuit Voltage Erratic,
between C-C61
Intermittent, or Incorrect
Proceed to Test Step 9.
Continued
Replace lower cab wiring harness
terminal 1.
(WP 0291).
Proceed to Test Step 9.
Test Step 5. Test Battery Voltage
Supply Circuit to Ignition Switch for
Short to Ground.
1. Disconnect connector C-C61
switch (WP 0254).
2. Disconnect connector C-C56
instrument cluster (WP 0252).
(WP 0174), test for continuity
harness (WP 0291).
between connector C-C61
Install new Monitoring/Key fuse
(TM 5-3805-298-10).
and machine ground.
Proceed to Test Step 9.
(WP 0254).
Install new Monitoring/Key fuse
(TM 5-3805-298-10).
Proceed to Test Step 9.
Test Step 6. Test Ignition Voltage
Supply Circuit for Short to Ground.
1. Disconnect connector C-C61
switch (WP 0254).
(WP 0174), test for continuity
(WP 0254).
Install new Monitoring/Key fuse
Figure 37) terminal 1 and ignition
(TM 5-3805-298-10).
switch housing, and to machine
Proceed to Test Step 9.
ground.
No Continuity - Proceed to step 3.
(WP 0174), test for continuity
(WP 0254).
Install new Monitoring/Key fuse
Figure 37) terminal 4 and ignition
(TM 5-3805-298-10).
switch housing, and to machine
Proceed to Test Step 9.
ground.
No Continuity - Proceed to step 4.
0116-5