TM 5-3805-298-23-1
0119
Table 1. Blower Motor Does Not Operate in One or More Speeds - Continued.
0119
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 15. Test for Open Blower
Blower Motor Does Not
Resistor.
Operate in One or More
1. Disconnect terminals 1, 2, and 3
Speeds - Continued
Figure 117).
Resistance 3.0 Ohms or Less
(WP 0174), measure resistance
Proceed to step 3.
between blower resistor
Replace blower resistor (WP 0420).
and terminal 3.
Proceed to Test Step 18.
Resistance 3.0 Ohms or Less
(WP 0174), measure resistance
Replace cab heater wiring harness
between blower resistor
(WP 0410).
Proceed to Test Step 18.
and terminal 2.
Replace blower resistor (WP 0420).
Proceed to Test Step 18.
Test Step 16. Test for Open Lower
Cab Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to ON position
(TM 5-3805-298-10).
2. Turn heater A/C switch to heater
ON (TM 5-3805-298-10).
Voltage 18 to 26 V Replace lower cab
(WP 0174), measure voltage
wiring harness (WP 0291).
between connector C-C14.
Proceed to Test Step 18.
Less Than 18 V Proceed to Test
and ground.
Step 17.
Test Step 17. Test for Open Lower
Cab Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Disconnect connector C-C16
A/C switch.
3. Turn ignition switch and battery
disconnect switch to ON position
(TM 5-3805-298-10).
0119-8