TM 5-3805-298-23-1
0121
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Condenser Fan(s) Do Not
Test Step 17. Test for Open Auxiliary
Operate When the Heater A/C
Air Conditioning Condenser Fan
Switch Is in A/C Position -
Wiring Harness.
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Disconnect connector MC-C2
auxiliary condenser fan relay.
3. Install a jumper wire between
terminal A and terminal B of
Figure 132).
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
Proceed to step 5.
between connector MC-C2
Replace auxiliary air conditioning
and terminal 2.
condenser fan wiring harness
(WP 0419).
Proceed to Test Step 33.
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
Proceed to step 6.
between connector MC-C1
Replace auxiliary air conditioning
condenser fan wiring harness
terminal 5.
(WP 0419).
Proceed to Test Step 33.
6. Remove jumper wire from terminal
A and terminal B of connector MC-
7. Install a jumper wire between
terminal 4 and terminal 5 of
Figure 137).
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
between connector MC-C3
(WP 0419).
Proceed to Test Step 33.
and terminal 2.
Replace auxiliary air conditioning
condenser fan wiring harness
(WP 0419).
Proceed to Test Step 33.
0121-11