Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 26. Test for Open Air
Condenser Fan(s) Do Not
Conditioning Condenser Fans
Operate When the Heater A/
Wiring Harness.
C Switch Is in A/C Position -
Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Disconnect connector MA-C4
3. Install a jumper wire between
terminal A and terminal B of
Figure 130).
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
Proceed to step 5.
between connector MA-C4
and terminal 2.
fans wiring harness (WP 0418).
Proceed to Test Step 33.
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
Proceed to step 6.
between connector MA-C2
fans wiring harness (WP 0418).
terminal 5.
Proceed to Test Step 33.
6. Remove jumper wire from terminal
A and terminal B of connector MA-
7. Install a jumper wire between
terminal 4 and terminal 5 of
Figure 136).
Resistance 5.0 Ohms or Less
(WP 0174), measure resistance
Replace condenser fans relay
between connector MA-C1
(WP 0417).
Proceed to Test Step 33.
and terminal 2.
fans wiring harness (WP 0418).
Proceed to Test Step 33.
Test Step 27. Test A/C BKR Circuit
Breaker Reset.
1. Turn battery disconnect switch ON
and start the machine (TM 5-3805-
298-10).