RELIEF VALVE PRESSURE FOR ROD END TILT CYLINDER TEST
Figure 44. Head End of Tilt Cylinder Pressure Port.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  366    367    368    369    370  371  372    373    374    375    376  
img
.
TM 5-3805-298-23-2
0166
RELIEF VALVE PRESSURE FOR ROD END TILT CYLINDER TEST CONTINUED
1. Apply sealant on threads of 5,800 psi (40,000 kPa) gauge (Figure 43, Item 1) and a 6V-3966 valved nipple
(Figure 43, Item 3) from pressure gauge kit.
2. Install adapter (Figure 43, Item 2) on 5,800 psi (40,000 kPa) gauge (Figure 43, Item 1).
3. Install 6V-3966 valved nipple (Figure 43, Item 3) on adapter (Figure 43, Item 2).
4. Connect hose 177-7861 (Figure 43, Item 4), from pressure gauge kit, to 6V-3966 valved nipple
(Figure 43, Item 3).
Figure 43. 5,800 psi (40,000 kPa) Gauge Assembly.