TM 5-3805-298-23-2
0177
REMOVAL CONTINUED
CAUTION
Cap all hydraulic openings along with component connections during removal to protect
against contamination. Failure to follow this caution may result in damage to equipment.
NOTE
Tag and mark all hoses and tubes to aid in installation.
Note routing of hoses and tubes for installation.
44. Loosen tube nut (Figure 24, Item 5) and remove hose (Figure 24, Item 4) and O-ring (Figure 24, Item 6) from
quick coupler solenoid valve (Figure 24, Item 1). Discard O-ring.
45. Loosen tube nut (Figure 24, Item 9) and remove hose (Figure 24, Item 8) and O-ring (Figure 24, Item 12) from
quick coupler solenoid valve (Figure 24, Item 1). Discard O-ring.
46. Loosen tube nut (Figure 24, Item 10) and remove hose (Figure 24, Item 7) and O-ring (Figure 24, Item 11) from
quick coupler solenoid valve (Figure 24, Item 1). Discard O-ring.
47. Disconnect quick coupler solenoid connector (Figure 24, Item 14) from front frame wiring harness connector
(Figure 24, Item 13).
48. Remove two bolts (Figure 24, Item 3), washers (Figure 24, Item 2) and quick coupler solenoid valve
(Figure 24, Item 1) from machine.
Figure 24. Quick Coupler Solenoid Valve.
0177