AIR CLEANER HOUSING HOSE INSTALLATION CONTINUED
7. Install hose clamp (Figure 13, Item 5) on air cleaner housing outlet hose (Figure 13, Item 4). Do not tighten.
8. Install air cleaner housing inlet hose (Figure 13, Item 2) and two hose clamps (Figure 13, Item 3) on engine
enclosure (Figure 13, Item 1). Do not tighten.
9. Install air cleaner housing (see procedure in this work package).
10. Install air inlet restriction switch (WP 0206).
11. Tighten all hose clamps installed on air cleaner housing hoses.
Figure 13. Air Cleaner Housing Inlet Hose.