Figure 14. Air Cleaner Housing.
Figure 16. Secondary Air Filter.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  886    887    888    889    890  891  892    893    894    895    896  
img
.
TM 5-3805-298-23-2
0204
AIR CLEANER HOUSING INSTALLATION CONTINUED
3. Connect air cleaner housing inlet hose (Figure 15, Item 4) to air cleaner housing (Figure 15, Item 5).
4. Connect air cleaner housing outlet hose (Figure 15, Item 1) to air cleaner housing (Figure 15, Item 5).
5. Install two hose clamps (Figure 15, Item 3) on air cleaner housing inlet hose (Figure 15, Item 4).
6. Install hose clamp (Figure 15, Item 2) on air cleaner housing outlet hose (Figure 15, Item 1) and tighten.
7. Install air cleaner filter elements (see procedure in this work package).
Figure 15. Hose Clamps.
0204
END OF TASK