TM 5-3805-298-23-4
0415
REMOVAL
000415
CAUTION
Cap all A/C lines and fittings during removal to protect against contamination. Failure to
follow this caution may result in equipment damage.
NOTE
Tag and note routing of hoses to aid installation.
Plug or cap all hoses and open ports.
1. Loosen tube nut (Figure 1, Item 1) and remove hose (Figure 1, Item 3) and O-ring (Figure 1, Item 2) from
fitting. Discard O-ring (Figure 1, Item 2).
2. Loosen tube nut (Figure 1, Item 6) and remove hose (Figure 1, Item 4) and O-ring (Figure 1, Item 5) from
fitting. Discard O-ring (Figure 1, Item 5).
3. Remove nut (Figure 1, Item 8), two washers (Figure 1, Item 9), and bolt (Figure 1, Item 7) from two clips
(Figure 1, Items 10 and 11).
4. Remove clips (Figure 1, Items 10 and 11) from accumulator (Figure 1, Item 13).
5. Remove grommet (Figure 1, Item 12) from accumulator (Figure 1, Item 13).
6. Remove accumulator (Figure 1, Item 13) from machine.
Figure 1. A/C Accumulator.
0415
END OF TASK
CLEANING AND INSPECTION
000415
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK