TM 5-3805-298-23-4
0418
REMOVAL CONTINUED
NOTE
Tag and mark wiring harness connectors and note wiring harness routing to aid
installation.
Note position and quantity of tiedown straps to aid installation.
2. Remove tiedown straps (Figure 2, Item 6) from air conditioning condenser fan wiring harness
(Figure 2, Item 3). Discard tiedown straps.
3. Disconnect air conditioning fan wiring harness connector (Figure 2, Item 7) from rear frame wiring harness
connector (Figure 2, Item 8).
4. Disconnect air conditioning fan wiring harness connector (Figure 2, Item 5) from left condenser fan connector
(Figure 2, Item 4).
5. Disconnect air conditioning fan wiring harness connector (Figure 2, Item 9) from right condenser fan connector
(Figure 2, Item 10).
6. Disconnect air conditioning fan wiring harness connector (Figure 2, Item 2) from condenser fan relay
(Figure 2, Item 1).
7. Remove air conditioning condenser fan wiring harness (Figure 2, Item 3) from machine.
8. Remove bolt (Figure 2, Item 11), washer (Figure 2, Item 12) and condenser fan relay (Figure 2, Item 1) from
machine.
Figure 2. Air Conditioning Condenser Fan Wiring Harness.
0418
END OF TASK
CLEANING AND INSPECTION
000418
Clean and inspect all parts IAW Electrical General Maintenance Instructions (WP 0174).
END OF TASK