TM 5-3805-298-23-4
0418
INSTALLATION
000418
NOTE
Install wiring harness connectors and route wiring harness as noted during removal.
Install tiedown straps as noted during removal.
1. Install condenser fan relay (Figure 2, Item 1), washer (Figure 2, Item 12), and bolt (Figure 2, Item 11) on
machine.
2. Position air conditioning condenser fan wiring harness (Figure 2, Item 3) on machine.
3. Connect air conditioning fan wiring harness connector (Figure 2, Item 2) on condenser fan relay
(Figure 2, Item 1).
4. Connect air conditioning fan wiring harness connector (Figure 2, Item 9) on right condenser fan connector
(Figure 2, Item 10).
5. Connect air conditioning fan wiring harness connector (Figure 2, Item 5) on left condenser fan connector
(Figure 2, Item 4).
6. Connect air conditioning fan wiring harness connector (Figure 2, Item 7) on rear frame wiring harness
connector (Figure 2, Item 8).
7. Install new tiedown straps (Figure 2, Item 6) on air conditioning condenser fan wiring harness
(Figure 2, Item 3).
8. Install cover (Figure 3, Item 1), two brackets (Figure 3, Item 4), 10 washers (Figure 3, Item 3), and bolts
(Figure 3, Item 2) on machine.
Figure 3. Air Conditioning Condenser Cover.
0418
END OF TASK
FOLLOW-ON TASKS
000418
Verify correct operation of machine (TM 5-3805-298-10).
END OF TASK
END OF WORK PACKAGE