TM 5-2420-231-10
0023
SERVICING PROCEDURES - Continued
1. Engage parking brake.
2. Remove protective cap.
3. Use tire pressure gage and check front and rear tires for proper inflation (38 psi (262 kPa) on rear tires
and 50 psi (345 kPa) on front tires). If pressure is low, do steps 4 thru 8 below.
4. Connect air hose (Figure 13, Item 2) with self-locking air chuck to valve (Figure 13, Item 1) on tire.
5. Connect remote shutoff valve (Figure 13, Item 3) to air source.
6. Stand behind tire tread and inflate tire to correct pressure.
7. Disconnect remote shutoff valve (Figure 13, Item 3).
8. Disconnect air hose (Figure 13, Item 2).
9. Install protective cap.
Figure 13. Tire Pressure.