Table 1. Batteries Do Not Maintain Charge - Continued.
08
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Batteries Do Not Maintain
Charge - Continued
Leave NATO slave cable on terminal in following step.
6. Remove nut (Figure 5, Item 2) and
four cables (Figure 5, Item 1) from
machine positive terminal
(Figure 5, Item 3).
Figure 5. Machine Positive Terminal.
0008
Continuity - Proceed to step 8.
continuity between positive termi-
nal (Figure 6, Item 2) and inner
receptacle (WP 0197).
ring (Figure 6, Item 5) of NATO
Install four cables and nut on machine
slave receptacle. There should be
positive terminal.
continuity.
Proceed to Test Step 6.
Continuity - Replace NATO slave
continuity between positive termi-
receptacle (WP 0197).
nal (Figure 6, Item 2) and outer
Proceed to Test Step 6.
ring (Figure 6, Item 4) of NATO
slave receptacle. There should be
no continuity.
Continuity - Proceed to step 10.
continuity between positive termi-
nal (Figure 6, Item 2) and machine
(WP 0198).
positive terminal (Figure 6, Item 6).
Proceed to Test Step 6.
There should be continuity.