TM 5-2420-231-23-1
0010
Table 1. Engine Cranks but Does Not Run - Continued.
010
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Cranks but Does Not
continuity between main chassis
Run - Continued
harness is shorted. Replace main
wiring harness connector terminal
chassis wiring harness (WP 0154).
Replace fuel shutoff fuse and install
machine ground. There should be
fuse panel cover (TM 5-2420-231-10).
no continuity.
Proceed to Test Step 8.
No Continuity - Proceed to step 5.
continuity between front console
harness is shorted. Replace front
wiring harness connector terminal
console wiring harness (WP 0163).
machine ground. There should be
no continuity.
Figure 3).
Replace fuel shutoff fuse (TM 5-2420-
231-10).
Proceed to Test Step 8.
faulty. Replace high-pressure fuel
pump (WP 0142).
Connect front console wiring harness
chassis wiring harness connector
Replace fuel shutoff fuse (TM 5-2420-
231-10).
Proceed to Test Step 8.
Test Step 8. Verify That Symptom Is
Resolved.
Start and operate engine. Engine
Engine Starts and Runs -
should start and run.
Troubleshooting complete.
Symptom Remains - Repeat
troubleshooting from the beginning.
END OF WORK PACKAGE
0010-13/(14 blank)