TM 5-2420-231-23-1
0010
Table 1. Engine Cranks but Does Not Run - Continued.
010
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Remove instrument panel front
Engine Cranks but Does Not
covers (WP 0174) and disconnect
Run - Continued
front console wiring harness con-
nector (Figure 7, Item 2) from
engine stop switch (Figure 7,
Item 1).
Figure 7. Engine Stop Switch.
0010
6. Turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
Voltage 10 to 14 Volts - Proceed to
sure voltage between front console
step 8.
wiring harness connector terminal
Voltage Less Than 10 Volts - Replace
front console wiring harness (WP
machine ground. Voltage should
0162).
be 10 to 14 volts.
Proceed to Test Step 8.
8. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10).