TM 5-2420-231-23-1
0010
Table 1. Engine Cranks but Does Not Run - Continued.
010
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Cranks but Does Not
Test Step 6. Test Fuel Shutoff
Run - Continued
1. Disconnect fuel shutoff wiring har-
ness connector (Figure 6, Item 1)
from main chassis wiring harness
connector (Figure 6, Item 2).
Figure 6. Fuel Shutoff Solenoid.
0010
2. Turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
Voltage 10 to 14 Volts - Fuel shutoff
sure voltage between main chas-
sis wiring harness connector
pressure fuel pump (WP 0142).
Install fuse panel cover (TM 5-2420-
and machine ground. Voltage
231-10).
should be 10 to 14 volts.
Proceed to Test Step 8.
Voltage Less Than 10 Volts - Proceed
to step 4.
4. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10).