• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 17. Cold Start Wiring Harness Connector.
Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  225    226    227    228    229  230  231    232    233    234    235  
img
.
TM 5-2420-231-23-1
0011
Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.
011
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
19. Turn ignition switch to the off posi-
Voltage 10 to 14 Volts During
Hard Start in Cold
tion (TM 5-2420-231-10).
Cranking - Replace grid heater wiring
Temperatures (50F or
harness (WP 0161).
Below) - Continued
Proceed to Test Step 9.
Voltage Less Than 10 Volts During
Cranking - Replace main chassis
wiring harness (WP 0154).
Proceed to Test Step 9.
Test Step 8. Test Heater Grid Relays
and Cold Start Relay.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Connect the fuel shutoff wiring har-
ness connector (Figure 18, Item 1)
to the main chassis wiring harness
connector (Figure 18, Item 2) (WP
0160).
Figure 18. Fuel Shutoff Solenoid.
0011
0011-21


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.