Table 1. Hard Start in Cold Temperatures (50F or Below) - Continued.
011
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. Crank engine (TM 5-2420-231-10).
Hard Start in Cold
Temperatures (50F or
Voltage 10 to 14 Volts - Proceed to
Below) - Continued
sure voltage between heater grid
step 10.
relay wiring harness connector
Voltage Less Than 10 Volts - Proceed
to step 15.
and machine ground. Voltage
should be 10 to 14 volts.
10. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
Resistance 5.0 Ohms or Less -
sure resistance between heater
Proceed to step 12.
grid controller wiring harness con-
Proceed to step 13.
nal 8 and machine ground.
Resistance should be 5.0 ohms or
less.
Resistance 5.0 Ohms or Less -
sure resistance between cold start
Proceed to Test Step 8.
relay wiring harness connector
Proceed to step 13.
and machine ground. Resistance
should be 5.0 ohms or less.
13. Disconnect grid heater wiring har-
ness connector (Figure 17, Item 1)
from main chassis wiring harness
connector (Figure 17, Item 2).
Resistance 5.0 Ohms or Less -
sure resistance between engine
Replace grid heater wiring harness
wiring harness connector (WP
(WP 0161).
0007, Figure 16) terminal 4 and
Proceed to Test Step 9.
machine ground. Resistance
should be 5.0 ohms or less.
Verify that right-front chassis ground
(Figure 16, Item 1) is clean and tight. If
ground is OK, replace main chassis
wiring harness (WP 0154).
Proceed to Test Step 9.