TM 5-2420-231-23-1
0018
Table 1. Instrument Cluster Does Not Function - Continued.
018
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Turn ignition switch to the on posi-
Instrument Cluster Does Not
tion (TM 5-2420-231-10).
Function - Continued
Voltage 10 to 14 Volts - Proceed to
sure voltage between side console
step 6.
wiring harness connector (WP
Voltage Less Than 10 Volts - Proceed
0007, Figure 28) terminal 1 and
to Test Step 3.
machine ground. Voltage should
be 10 to 14 volts.
Voltage 10 to 14 Volts - Replace
sure voltage between instrument
instrument cluster (WP 0177).
cluster wiring harness connector
Proceed to Test Step 4.
Voltage Less Than 10 Volts - Proceed
and 36. Voltage should be 10 to 14
to step 7.
volts.
0018-7