TM 5-2420-231-23-1
0018
Table 1. Instrument Cluster Does Not Function - Continued.
018
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Instrument Cluster Does Not
Test Step 2. Test Instrument Cluster
Function - Continued
Voltage Supply and Ground Circuits.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Remove two screws (Figure 4,
Item 2) from instrument panel
cluster (Figure 4, Item 1), pull
instrument panel cluster (Figure 4,
Item 1) from bezel (Figure 4,
Item 3), and disconnect side
console wiring harness connector
Figure 28) from instrument panel
cluster (Figure 4, Item 1) (WP
Figure 4. Instrument Cluster.
0018
3. Install instrument alarm fuse (TM
5-2420-231-10).