TM 5-2420-231-23-1
0022
Table 1. Transmission Temperature Gauge Indicates High Temperature,
Does Not Function, or Is Inaccurate - Continued.
022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Transmission Temperature
Test Step 4. Test Transmission
Gauge Indicates High
Temperature Gauge.
Temperature, Does Not
1. Turn ignition switch to the off posi-
Function, or Is Inaccurate -
tion (TM 5-2420-231-10) and dis-
Continued
connect batteries (WP 0157).
2. Remove locknut (Figure 11,
Item 1) and transmission tempera-
ture sender eyelet (Figure 11,
Item 3) from transmission temper-
ature sender (Figure 11, Item 2).
Figure 11. Transmission Temperature Sender.