Table 1. Transmission Temperature Gauge Indicates High Temperature,
Does Not Function, or Is Inaccurate - Continued.
022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Transmission Temperature
6. Remove two screws (Figure 13,
Gauge Indicates High
Item 2) and pull instrument panel
Temperature, Does Not
cluster (Figure 13, Item 1) from
Function, or Inaccurate -
side console.
Continued
7. Disconnect side console wiring
harness connector (Figure 13,
Item 3) from instrument cluster
(Figure 13, Item 1).
Figure 13. Instrument Cluster.
0022
Continuity - Proceed to step 9.
wiring harness connector (WP
cluster (WP 0177).
0007, Figure 28) terminal 21 and
Connect all wiring harness connectors.
machine ground. There should be
Proceed to Test Step 7.
no continuity.
9. Remove front instrument panel
right-side cover (WP 0176).